Monitoring and classification of PAH toxicity using an immobilized bioluminescent bacteria
Hyun Joo Lee1, Julien Villaume, David C Cullen
1National Research Laboratory on Environmental Biotechnology, Kwangju Institute of Science and Technology (K-JIST), 1 Oryong-dong, Puk-gu, 500-712, Kwangju, South Korea.
Abstract:
An immobilized recombinant bioluminescent Escherichia coli strain, harboring a lac::luxCDABE fused plasmid, which shows lower bioluminescence levels when cellular metabolism is inhibited, was used to monitor the cellular toxicity of polycyclic aromatic hydrocarbons (PAHs). PAHs, classified as pericondensed (PCPAHs) or catacondensed (CCPAHs) according to their molecular structures, were differentiable according to the response of this biosensor. Only CCPAHs were found to cause cellular toxicity, resulting in a dose-dependent decrease in the bioluminescent output. The induction of cellular toxicity by CCPAHs and PCPAHs was compared with acute toxicity predictions obtained using the quantitative structure-activity relationship (QSAR) model. A good relationship was obtained between the toxicities determined with the bioluminescent response of the immobilized bacterium GC2 and the QSAR model. It was also found that the present study offers a new method of predicting the cellular toxicities of CCPAHs or PCPAHs using this biosensor.
More Related Videos
04:47Autonomously Bioluminescent Mammalian Cells for Continuous and Real-time Monitoring of Cytotoxicity
Published on: October 28, 2013
09:15Come to the Light Side: In Vivo Monitoring of Pseudomonas aeruginosa Biofilm Infections in Chronic Wounds in a Diabetic Hairless Murine Model
Published on: October 10, 2017