Related Experiment Video
Updated: Aug 5, 2026

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
Calculation and measurement of the magnetic field in a large diameter electromagnetic flow meter
1Department of Engineering Physics, Tsinghua University, Beijing, 100084, P.R. China.
Abstract:
An idealized magnet model previously used in a simple coil configuration is applied to a more complicated engineering design problem, where an electromagnetic flow meter in diameter of 500 mm is used with five pairs of coils. The numerical results are compared with measurement data. The difference between theory and experiment and the possible causes of errors are discussed. It is shown that the idealized magnet model is practical for the design and the analysis of the flow meter. The work also shows that the traditional uniform field design based on two dimensional (2D) analysis is not suitable for this kind of flow meter. Thus nonuniform field and 3D analysis is needed.
More Related Videos
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
Related Concept Videos
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Field Due To A Thin Straight Wire
Magnetic Field Of A Current Loop
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
Calculation of Self-inductance
Since the effect of the induced electric field and the back EMF generated depends on the rate of change of current and the self-inductance, the inductance...