ICD leads: design and chronic dysfunctions.

Rainer Gradaus1, Günter Breithardt, Dirk Böcker

  • 1Medizinische Klinik und Poliklinik C (Kardiologie und Angiologie), Universitätsklinikum Münster, D-48129 Münster, Germany. gradaus@uni-muenster.de

Pacing and Clinical Electrophysiology : PACE
|April 25, 2003
PubMed
Summary

Implantable cardioverter defibrillators (ICDs) are now the preferred treatment for ventricular tachyarrhythmias, driven by technological advancements in leads. However, lead failures remain a significant complication, necessitating careful consideration for extraction versus retention.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effectiveness and Safety of Early Rhythm Control in Patients With Atrial Fibrillation and Chronic Kidney Disease.

Journal of the American College of Cardiology·2026
Same author

Transforming atrial fibrillation management by targeting comorbidities and reducing atrial fibrillation burden: the 10th AFNET/EHRA consensus conference.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2025
Same author

Prevalence and severity of atrial cardiomyopathy in patients with recently diagnosed atrial fibrillation and stroke risk factors and its association with early rhythm control: a secondary analysis of EAST-AFNET 4.

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology·2025
Same author

Case report: inadvertent misplacement of pacemaker leads in the left ventricle and left circumflex artery.

European heart journal. Case reports·2025
Same author

Safety and efficacy of amiodarone and dronedarone for early rhythm control in EAST-AFNET 4.

Clinical research in cardiology : official journal of the German Cardiac Society·2025
Same author

Apixaban, edoxaban and rivaroxaban but not dabigatran are associated with higher mortality compared to vitamin-K antagonists: A retrospective German claims data analysis.

Journal of internal medicine·2024

Area of Science:

  • Cardiology
  • Biomedical Engineering

Background:

  • Implantable cardioverter defibrillators (ICDs) have transitioned from last-resort therapy to the primary treatment for ventricular tachyarrhythmias over the past decade.
  • This shift predates randomized study results, largely driven by technological innovations, particularly transvenous leads.

Purpose of the Study:

  • To review the evolution of ICD therapy and its associated lead technology.
  • To highlight the increasing clinical importance of ICD lead failures as ICD use expands.
  • To discuss the clinical dilemma of lead extraction versus retention in cases of failure.

Main Methods:

  • Review of technological advancements in ICD lead design, including materials and construction.
  • Analysis of common lead failure modes and their causes.

Related Experiment Videos

  • Discussion of the clinical implications of lead failures and extraction procedures.
  • Main Results:

    • Modern ICD leads feature multilumen designs with advanced insulation materials (silicone, polyurethane, fluoropolymers).
    • Lead failures, including conductor fractures and insulation defects, are inevitable complications of chronically implanted devices.
    • The increasing prevalence of ICDs makes lead failures a growing clinical concern.

    Conclusions:

    • Despite technological progress, ICD lead failures remain a significant challenge.
    • Decisions regarding lead extraction require careful consideration of lead type, failure mode, and extraction risks.
    • Optimizing lead performance and management strategies is crucial for improving patient outcomes in ventricular tachyarrhythmia treatment.