Abstract
Purpose:
To compare White & White and Blue-Yellow Full Threshold automated perimetry.
Material And Method:
Group of 37 patients; we used a Humphrey Zeiss automated perimeter.
Results:
We obtained 49% abnormal white & white visual fields and 62% abnormal blue yellow fields.
Conclusions:
Blue Yellow perimetry has higher sensibility than white & white perimetry. We can detect earlier with this test the glaucoma defects.