Detection of speaking with a new respiratory inductive plethysmography system
Related Experiment Video
Updated: Sep 26, 2026

Simplified Whole Body Plethysmography to Characterize Lung Function During Respiratory Melioidosis
Published on: February 24, 2023
Frank H Wilhelm1, Eva M Handke, Walton T Roth
1Department of Psychiatry and Behavioral Sciences, Stanford University School of Medicine, Stanford, CA 94305, USA.
Abstract:
The LifeShirt system, a garment with integrated sensors connected to a handheld computer, allows recording of a wide variety of clinically important cardiorespiratory data continuously for extended periods outside the laboratory or clinic. The device includes sensors for assessment of physical activity and posture since both can affect physiological activation and need to be controlled. Speaking is another potential confounding factor in the interpretation of physiological data. Auditory speech recording is problematic because it can pick up sources other than the person's voice (external microphone) or is obtrusive (throat microphone). The abdominal and thoracic calibrated respiratory inductive plethysmography (RIP) sensors integrated in the LifeShirt system might be an adequate alternative for detecting speech. In a laboratory experiment we determined respiratory parameters indicative of speech. Eighteen subjects were instructed to sit quietly, write, and speak continuously, for 4 min each. Nine parameters were derived from the RIP signals and averaged over each minute. In addition, nine variability parameters were computed as their coefficients of breath-by-breath variation. Inspiratory/expiratory time (IE-ratio) best distinguished speaking from writing with 98% correct classification at a cutoff criterion of 0.52. This criterion was equally successful in distinguishing speaking from sitting quietly. Discriminant analyses indicated that linear combinations of IE-ratio and a variety of other parameters did not reliably improve classification accuracy across tasks and replications. These results demonstrate the high efficacy of RIP-derived IE-ratio for speech detection and suggest that auditory recording is not necessary for detection of speech in ambulatory assessment.
Related Concept Videos
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...

