Digital signal processing methods for the evaluation of Blood Volume Pulse (BVP) waveform changes due to exercise
Related Experiment Video
Updated: Sep 10, 2026

A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Chao Li1, Jing Zhai, Armando Barreto
1Digital Signal Processing Laboratory, Electrical & Computer Engineering Department, Florida International University, Miami, FL 33174, USA.
Abstract:
Previous research by our group has revealed that the Blood Volume Pulse (BVP) waveform recorded using an infrared finger photoplethysmograph (PPG) undergoes changes as the subject performs physical exercise. In particular, a reduction in the depth of the Dicrotic Notch has been observed. There is an interest in characterizing those changes through a single parameter to measure the level of exercise the subject has reached, at any time during an exercise session. This paper reports on the comparison of three Digital Signal Processing approaches designed to reflect the BVP waveform changes through a single parameter, which could be obtained automatically from the digitized BVP signal. The first approach derives a single parameter from the distribution found in the average histogram of several time-aligned and averaged BVP beats. Our second approach analyzes the ratio observed between the first harmonic and higher harmonics in the BVP signal. The third approach evaluates the Dicrotic Notch depth directly from the BVP waveform, tracking sample values about the local minimum defined by the Dicrotic Notch. Our study, involving observations from 10 subjects, ranks these three approaches according to their ability to reflect the changes in BVP due to exercise.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical indicator...