A comparison of abdominal ECG and Doppler ultrasound for fetal heart rate detection
Muhammad I Ibrahimy1, M A Mohd Ali, Edmond Zahedi
1Information Processing Laboratory, Department of Electrical and Electronic Engineering, Faculty of Engineering, Mie University, Tsu, Mie 514-8507, Japan.
A fetal monitor has been developed for the measurement of the fetal and maternal heart rates from maternal abdominal electrocardiogram during pregnancy and labor for ambulatory monitoring. Developed algorithm of the fetal monitor is based on digital filtering, adaptive thresholding. statistical properties in the time domain and differencing of local maxima and minima. Five volunteers with low risk pregnancies, between 35 to 40 weeks of gestation and no evidence of labor, were studied for the fetal heart rate detection. A Doppler ultrasound fetal monitor was used to compare the accuracy of the measurement system. Results showed an average percent rms difference (PRD) of 5.32% in comparison with the reference ultrasound method. The fetal heart rates curve remained inside a +/- 5 beats/min limit relative to the reference ultrasound method for 84.1% of the time.
A fetal monitor has been developed for the measurement of the fetal and maternal heart rates from maternal abdominal electrocardiogram during pregnancy and labor for ambulatory monitoring. Developed algorithm of the fetal monitor is based on digital filtering, adaptive thresholding. statistical properties in the time domain and differencing of local maxima and minima. Five volunteers with low risk pregnancies, between 35 to 40 weeks of gestation and no evidence of labor, were studied for the fetal heart rate detection. A Doppler ultrasound fetal monitor was used to compare the accuracy of the measurement system. Results showed an average percent rms difference (PRD) of 5.32% in comparison with the reference ultrasound method. The fetal heart rates curve remained inside a +/- 5 beats/min limit relative to the reference ultrasound method for 84.1% of the time.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...