The Millikan modified mesh-plug hernioplasty.

Keith W Millikan1, Brice Cummings, Alexander Doolas

  • 1Department of General Surgery, Rush-Presbyterian-St Luke's Medical Center, Chicago, IL 60612, USA. Keith_Millikan@rush.edu

Archives of Surgery (Chicago, Ill. : 1960)
|May 14, 2003
PubMed
Summary

This modified mesh-plug hernioplasty is safe and effective for inguinal hernia repair. It offers a fast recovery, minimal pain, and a low recurrence rate for patients.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Early Diagnosis and Treatment of Chylous Mesenteric Cysts.

The American surgeon·2020
Same author

Outcomes in complex ventral hernia repair with anterior component separation in class III obesity patients.

American journal of surgery·2018
Same author

Myoepithelial Carcinoma of the Thigh after Lipoma Excision.

The American surgeon·2017
Same author

The effect of tobacco use on outcomes of laparoscopic and open ventral hernia repairs: a review of the NSQIP dataset.

Surgical endoscopy·2016
Same author

Gastric Adenocarcinoma Presenting after Revisional Roux-en-Y Gastric Bypass.

The American surgeon·2016
Same author

The effect of tobacco use on outcomes of laparoscopic and open inguinal hernia repairs: a review of the NSQIP dataset.

Surgical endoscopy·2016

Area of Science:

  • Surgical Innovation
  • Hernia Repair Techniques
  • Minimally Invasive Surgery

Background:

  • Inguinal hernias are common surgical conditions requiring effective repair.
  • Traditional hernioplasty techniques can involve significant recovery times and postoperative discomfort.

Purpose of the Study:

  • To evaluate the safety and efficacy of a modified mesh-plug hernioplasty technique.
  • To assess outcomes including recurrence, pain, and return to activities.

Main Methods:

  • Prospective analysis of 1056 patients undergoing primary unilateral inguinal hernioplasty.
  • Utilized a modified mesh-plug technique under local anesthesia with IV sedation.
  • Outcomes measured included surgical morbidity, recurrence, pain medication use, and return to normal activities.

Related Experiment Videos

Main Results:

  • Mean operative time was 25 minutes; all procedures were outpatient.
  • 95.9% of patients returned to normal activities within 3 days; manual laborers returned to work in 14 days.
  • A low recurrence rate of 0.1% was observed at 1-year follow-up, with minimal complications.

Conclusions:

  • The modified mesh-plug hernioplasty is a safe, resource-efficient option for inguinal hernia repair.
  • It is associated with minimal postoperative pain and rapid return to activities.
  • This technique demonstrates a low recurrence rate and should be considered a gold standard.