Conduction properties of accessory atrioventricular pathways: importance of the accessory pathway location and normal
Shaowen Liu1, Shiwen Yuan, S Bertil Olsson
1Department of Cardiology, University Hospital, Lund University, SE-221 85 Lund, Sweden.
Objective:
The objective of this study was to determine the conduction properties of the normal atrioventricular (AV) conduction system in relation to accessory pathway (AP) location in patients with symptomatic Wolff-Parkinson-White syndrome.
Design:
The conduction properties of the AP and the AV node were studied in 356 patients with single manifest AP who underwent successful ablation.
Results:
Sixty-three percent of the APs were located on the left free wall (226) and the remaining 37% were posteroseptal, anteroseptal and right free wall. AV block (PR > or =220 ms) was observed in 15 patients, 8 cases being associated with the right free wall (15%) compared with 7 on the left free wall (3%, p = 0.002) and none on the anteroseptal (p = 0.02) or posteroseptal (p = 0.007). The PR (182 +/- 30 ms) and AH (102 +/- 25 ms) intervals associated with right free wall AP were longer than left free wall (166 +/- 23, 88 +/- 21 ms, p < 0.0001, respectively), anteroseptal (155 +/- 11, 79 +/- 12 ms, p < 0.0001) and posteroseptal AP (155 +/- 16, 79 +/- 13 ms, p < 0.0001), whereas the PR and AH intervals associated with posteroseptal and anteroseptal AP were shorter than left free wall AP (p < 0.05). When patients with AV block were excluded from the analysis, the PR intervals in patients with right free wall AP were still longer than in those with left free wall (p < 0.005), anteroseptal (p < 0.001) and posteroseptal AP (p < 0.0001), as were the PR intervals associated with left free wall AP compared with data of posteroseptal (p < 0.01) and anteroseptal AP (p < 0.05). Significant differences in AV nodal effective refractory period, anterograde and retrograde AV block cycle length were also observed in relation to AP location.
Conclusion:
The conduction properties of the normal AV conduction system are associated with specific AP location in patients with Wolff-Parkinson-White syndrome.
More Related Videos
Related Concept Videos
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials