Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
The application of diffusive sampling combined with thermal desorption in occupational exposure monitoring--field
Yeh-Chung Chien1, Li-Jue Wu, Jung-Hen Lwo
1Hungkuang Institute of Technology, Taichung, Taiwan.
Abstract:
Diffusive sampling combined with thermal desorption (DSTD) is considered useful in monitoring workers' exposures to organic vapors, not only due to its simplicity of operation in the field but, also, its simplifying the sample treatment, eliminating the use of extracting solvent, and increasing analytical sensitivity. Herein, the feasibility of applying DSTD in field conditions was assessed through a comparison of the results with those from the well-accepted active/charcoal method. Side-by-side active and diffusive (tube-type, Tenax TA as the adsorbent) samples, both personal and area, were collected and analyzed for xylenes, ethyl acetate, styrene, and n-butyl acetate in four different industrial settings. Statistically significant correlations were found between the two methods in personal samples with the correlation coefficients of 0.92, 0.90, 0.83, 0.88, and 0.97 for m&p-xylenes, o-xylene, n-butyl acetate, styrene, and ethyl acetate, respectively. A paired t-test revealed significant difference between the two methods for n-butyl acetate and styrene. For area sampling, statistical differences (p < 0.05) were found between the two methods, except for xylenes. The DSTD method had, mostly, a lower concentration than the active method, with the bias ranging from 10.2 to -54.4 percent. The possible causes for the discrepancies are discussed. These results suggest that though DSTD protocols can be considered as a simple approach for screening workers' exposures to volatile organics, they should be applied with caution since diffusive sampling is potentially affected by various environmental conditions and adsorptive characteristics.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Flame Photometry: Lab
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Atomization Methods