Atmospheric pressure electrospray ionization mass spectra of glucose and 2-fluorodeoxyglucose for quantitative
F Macásek1, P Brúder, A Patakyová
1Department of Nuclear Chemistry, Faculty of Natural Sciences, Comenius University, SK-84215 Bratislava, Slovakia. macasek@fns.uniba.sk
Abstract:
2-Fluoro-2-deoxy-D-glucose (FDG) labeled by fluorine-18 is the most widely used radiopharmaceutical for positron emission tomography (PET). For high-performance liquid chromatography (HPLC)/MS assay and quality control, the mass spectra of FDG and glucose (Glc) in organic + water solutions were studied by flow injection analysis (FIA) and in a chromatographic eluate. In acetonitrile (MeCN) + 0.025% ammonium formate (NH(4)HCO(2)) solvent (80 : 20), electrospray ionisation (ESI) of glucose-FDG provides M.NH(4)(+) and 2M.Na(+) (M = Glc or FDG) as the most intense positive ions. Formation of the latter ions and also of M.MeCN.Na(+) and 2MeCN. Na(+) is typical of the presence of NaCl in the ESI inlet. The positive ions include heavier ions corresponding to the impurities separated by HPLC and also to the cross-ring fragmentation of complexes (2FDG. aMeCNX)L, where a = 0 or 1, L is either Na(+) or NH(4)(+) and X is a fragmented pyranose or anhydropyranose residue. The second most abundant Glc negative ion is m/z = 359 which was interpreted as (2GlcH(+))(). The negative-ion spectrum of FDG has dominating lines due to FDG.HCO(2)() ions at m/z 227 and also (2FDGH(+))() at m/z 363. The m/z 363 signal is suppressed in the presence of NaCl at a molar ratio of 4 : 1 to NH(4)HCO(2), while the ions at m/z 217 and 219, i.e. FDG.Cl(), become three times more intense than FDG.HCO(2)(). The latter ion appears to be most suitable as an analytical signal for chemical analysis of FDG at m/z 226 and 227. Limits of FDG quantitation (LOQ) of 19 ng and 21 ng were found for the 200(+) and 227() ion signals, respectively, and are wholly adequate for verification of total FDG content in radiopharmaceuticals.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Electrophoresis: Overview
There...