The 2002 Denali fault earthquake, Alaska: a large magnitude, slip-partitioned event

Donna Eberhart-Phillips1, Peter J Haeussler, Jeffrey T Freymueller

  • 1U.S. Geological Survey, 4200 University Drive, Anchorage, AK 99508, USA.

Science (New York, N.Y.)
|May 17, 2003
PubMed

Related Concept Videos

Types of Collisions - II01:19

Types of Collisions - II

When two or more objects collide with each other, they can stick together to form one single composite object (after collision). The total mass of the object after the collision is the sum of the masses of the original objects, and it moves with a velocity dictated by the conservation of momentum. Although the system's total momentum remains constant, the kinetic energy decreases, and thus such a collision is an inelastic collision. Most of the collisions between objects in daily life are...
Elastic Collisions: Case Study01:15

Elastic Collisions: Case Study

Elastic collision of a system demands conservation of both momentum and kinetic energy. To solve problems involving one-dimensional elastic collisions between two objects, the equations for conservation of momentum and conservation of internal kinetic energy can be used. For the two objects, the sum of momentum before the collision equals the total momentum after the collision. An elastic collision conserves internal kinetic energy, and so the sum of kinetic energies before the collision equals...
Deformation of Member under Multiple Loadings01:11

Deformation of Member under Multiple Loadings

When a rod is made of different materials or has various cross-sections, it must be divided into parts that meet the necessary conditions for determining the deformation. These parts are each characterized by their internal force, cross-sectional area, length, and modulus of elasticity. These parameters are then used to compute the deformation of the entire rod.
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
Types of Building Separation Joints01:23

Types of Building Separation Joints

Building separation joints divide large or complex building structures into smaller, discrete units that can move independently. These joints are categorized into three types: volume-change joints, settlement joints, and seismic separation joints.
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200 feet...
Unsoundness of Aggregate due to Volume Change01:26

Unsoundness of Aggregate due to Volume Change

Unsoundness in aggregates due to volume changes is primarily caused by the physical alterations aggregates undergo, such as freezing and thawing, thermal changes, and wetting and drying. Unsound aggregates, when subjected to these changes, result in volume change upon disintegration. This, in turn, contributes to the deterioration of concrete, including scaling, pop-outs, and cracking. Particular types of aggregates, such as porous flints, cherts, and those containing clay minerals, are...