Related Experiment Video
Updated: Aug 10, 2026

Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Modified carpal box technique in the diagnosis of suspected scaphoid fractures
1Department of Traumatology, Pécs University, Medical School, Hungary. toth123@yahoo.com
Purpose:
To establish and test the clinical efficacy of a new diagnostic algorithm with the extensive utilization of modified carpal box radiography (mX-CB) in the detection of scaphoid fractures.
Material And Methods:
Initial and early follow-up radiographic evaluation of 146 suspected scaphoid fractures were carried out by mX-CB. Patients with unconfirmed diagnosis were referred to CT. Patients were followed for 1 year after injury. Sensitivity, specificity and interobserver agreement of reading mX-CB images were determined statistically.
Results:
No non-union or avascular necrosis was seen at 1 year after the injury. 90% of the fractures were diagnosed by mX-CB, only 6.8% of the patients needed referral to CT. Sensitivity of mX-CB at initial presentation was 81.6%. Interobserver agreement was very high among evaluators of mX-CB images.
Conclusion:
Extensive utilization of mX-CB as primary and early follow-up investigation resulted in high initial diagnostic accuracy and low referral rate to a more expensive diagnostic modality.