Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Analysis of the regional pulse wave velocity by Doppler: methodology and reproducibility
J-P Baguet1, B A Kingwell, A L Dart
1Department of Cardiology and Hypertension, University Hospital, Grenoble, France. JPBaguet@chu-grenoble.fr
Abstract:
Increased arterial stiffness is observed in a number of cases. The analysis of the regional functional arterial properties is of interest to determine the role of a given risk factor on the vascular wall and in some diseases such as atherosclerosis. We analysed the pulse wave velocity (PWV) measured by the Doppler method with 2D guidance and its reproducibility in different arterial segments in 15 men with coronary artery disease. Regional Doppler PWV was defined as the distance between the extremities of a given segment divided by the transit time calculated by Doppler. Intra- and interobserver reproducibilities of the Doppler measurements were studied in all of the subjects. The variation coefficients were low, maximum at the level of ascending aorta and minimal at the level of iliac segment. This good reproducibility was validated by the Bland-Altman method. Moreover, using this Doppler technique, we found a progressive increase in PWV from the ascending aorta to the iliac segment. These data demonstrate that noninvasive Doppler analysis is a feasible and reproducible method to determine regional PWV.
Related Concept Videos
Doppler Effect - II
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...