Related Experiment Video
Updated: Aug 6, 2026

An Experimental Paradigm for the Prediction of Post-Operative Pain (PPOP)
Published on: January 27, 2010
A multicenter, randomized, controlled trial comparing bupivacaine with ropivacaine for labor analgesia
Stephen H Halpern1, Terrance W Breen, David C Campbell
1Department of Anaesthesia, Sunnybrook and Women's Health Sciences Centre, Women's College Campus, University of Toronto, Toronto, Ontario, Canada. stephen.halpern@swchsc.on.ca
Background:
A meta-analysis of studies comparing high doses of bupivacaine with ropivacaine for labor pain found a higher incidence of forceps deliveries, motor block, and poorer neonatal outcome with bupivacaine. The purpose of this study was to determine if there is a difference in these outcomes when a low concentration of patient-controlled epidural bupivacaine combined with fentanyl is compared with ropivacaine combined with fentanyl.
Methods:
This was a multicenter, randomized, controlled trial, including term, nulliparous women undergoing induction of labor. For the initiation of analgesia, patients were randomized to receive either 15 ml bupivacaine, 0.1%, or 15 ml ropivacaine, 0.1%, each with 5 microg/ml fentanyl. Analgesia was maintained with patient-controlled analgesia with either local anesthetic, 0.08%, with 2 microg/ml fentanyl. The primary outcome was the incidence of operative delivery. We also examined other obstetric, neonatal, and analgesic outcomes.
Results:
There was no difference in the incidence of operative delivery between the two groups (148 of 276 bupivacaine recipients vs. 135 of 279 ropivacaine recipients; P = 0.25) or any obstetric or neonatal outcome. The incidence of motor block was significantly increased in the bupivacaine group compared with the ropivacaine group at 6 h (47 of 93 vs. 29 of 93, respectively; P = 0.006) and 10 h (29 of 47 vs. 16 of 41, respectively; P = 0.03) after injection. Satisfaction with mobility was higher with ropivacaine than with bupivacaine (mean +/- SD: 76 +/- 23 vs. 72 +/- 23, respectively; P = 0.013). Satisfaction for analgesia at delivery was higher for bupivacaine than for ropivacaine (mean +/- SD: 71 +/- 25 vs. 66 +/- 26, respectively; P = 0.037).
Conclusions:
There was no difference in the incidence of operative delivery or neonatal outcome among nulliparous patients who received low concentrations of bupivacaine or ropivacaine for labor analgesia.
Related Concept Videos
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Local Anesthetics: Common Agents and Their Applications
Cocaine is an ester of benzoic acid and methylecgogine. It is used to anesthetize and vasoconstrict locally. Currently, it is used primarily for topical applications. It is beneficial for surgeries on the upper respiratory tract, providing anesthesia and shrinking the mucosa. Cocaine in the form of cocaine hydrochloride is...
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
