Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure:
James B Young1, William T Abraham, Andrew L Smith
1Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA. youngj@ccf.org
Insights
Cardiac resynchronization therapy (CRT) combined with an implantable cardioverter defibrillator (ICD) significantly improved quality of life and exercise capacity in heart failure patients. The combined therapy proved safe, without increasing proarrhythmia or impairing ICD function.
Area of Science:
- Cardiology
- Electrophysiology
- Heart Failure Management
Background:
- Cardiac resynchronization therapy (CRT) using biventricular pacing is effective for heart failure (HF) with wide QRS.
- Outcomes for patients needing both CRT and implantable cardioverter defibrillator (ICD) therapy were previously unknown.
- This study investigated the combined efficacy and safety of CRT and ICD in severe HF patients.
Purpose of the Study:
- To evaluate the efficacy and safety of combined CRT and ICD therapy.
- To assess outcomes in patients with New York Heart Association (NYHA) class III or IV congestive heart failure.
- To determine effects despite optimal medical management.
Main Methods:
- A randomized, double-blind, parallel-controlled trial involving 369 patients with LVEF ≤ 35% and QRS duration ≥ 130 ms.
- Patients were at high risk for ventricular arrhythmias and NYHA class III/IV despite optimized medical treatment.
- Interventions included CRT (CRT on, ICD on) versus control (CRT off, ICD on).
Main Results:
- CRT group showed significant improvements in quality of life (P=.02) and functional class (P=.007) at 6 months.
- Peak oxygen consumption (P=.04) and treadmill exercise duration (P<.001) increased significantly with CRT.
- No significant differences were observed in left ventricular function, survival, or hospitalization rates; no proarrhythmia occurred.
Conclusions:
- Combined CRT and ICD therapy improves quality of life, functional status, and exercise capacity in selected HF patients.
- Improvements were achieved alongside optimal medical management without adverse effects on ICD function or increased proarrhythmia.
- CRT is a valuable addition for managing moderate to severe HF with wide QRS and high arrhythmia risk.
Context:
Cardiac resynchronization therapy (CRT) through biventricular pacing is an effective treatment for heart failure (HF) with a wide QRS; however, the outcomes of patients requiring CRT and implantable cardioverter defibrillator (ICD) therapy are unknown.
Objective:
To examine the efficacy and safety of combined CRT and ICD therapy in patients with New York Heart Association (NYHA) class III or IV congestive HF despite appropriate medical management.
Design, Setting, And Participants:
Randomized, double-blind, parallel-controlled trial conducted from October 1, 1999, to August 31, 2001, of 369 patients with left ventricular ejection fraction of 35% or less, QRS duration of 130 ms, at high risk of life-threatening ventricular arrhythmias, and in NYHA class III (n = 328) or IV (n = 41) despite optimized medical treatment.
Interventions:
Of 369 randomized patients who received devices with combined CRT and ICD capabilities, 182 were controls (ICD activated, CRT off) and 187 were in the CRT group (ICD activated, CRT on).
Main Outcome Measures:
The primary double-blind study end points were changes between baseline and 6 months in quality of life, functional class, and distance covered during a 6-minute walk. Additional outcome measures included changes in exercise capacity, plasma neurohormones, left ventricular function, and overall HF status. Survival, incidence of ventricular arrhythmias, and rates of hospitalization were also compared.
Results:
At 6 months, patients assigned to CRT had a greater improvement in median (95% confidence interval) quality of life score (-17.5 [-21 to -14] vs -11.0 [-16 to -7], P =.02) and functional class (-1 [-1 to -1] vs 0 [-1 to 0], P =.007) than controls but were no different in the change in distance walked in 6 minutes (55 m [44-79] vs 53 m [43-75], P =.36). Peak oxygen consumption increased by 1.1 mL/kg per minute (0.7-1.6) in the CRT group vs 0.1 mL/kg per minute (-0.1 to 0.8) in controls (P =.04), although treadmill exercise duration increased by 56 seconds (30-79) in the CRT group and decreased by 11 seconds (-55 to 12) in controls (P<.001). No significant differences were observed in changes in left ventricular size or function, overall HF status, survival, and rates of hospitalization. No proarrhythmia was observed and arrhythmia termination capabilities were not impaired.
Conclusions:
Cardiac resynchronization improved quality of life, functional status, and exercise capacity in patients with moderate to severe HF, a wide QRS interval, and life-threatening arrhythmias. These improvements occurred in the context of underlying appropriate medical management without proarrhythmia or compromised ICD function.
Related Concept Videos
Heart Failure V: Medical Management
Heart Failure VI: Adjunct Therapies
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Cardiomyopathy IV: Restrictive Cardiomyopathy
Cardiomyopathy V: Interprofessional Care


