Comparison of two different CPAP systems by tidal breathing parameters
Related Experiment Video
Updated: Sep 25, 2026

Method to Obtain Pattern of Breathing in Senescent Mice through Unrestrained Barometric Plethysmography
Published on: April 28, 2020
Thomas Hückstädt1, Bertram Foitzik, Roland R Wauer
1Clinic of Neonatology CCM, Humboldt-University, Medical School (Charité), Schumannstrasse 20/21, 10098, Berlin, Germany.
Objective:
Comparison of tidal breathing and pressure fluctuation of the continuous positive airway pressure (CPAP) associated with the use of the valveless Infant Flow System versus the conventional constant-flow CPAP (Babylog 8000) in preterm infants.
Design:
Randomized cross-over trial.
Setting:
Neonatal intensive care unit level III.
Patients:
Twenty infants; median (range): birth weight 1,035 g (640-4,110 g), actual weight 1,165 g (820-4,250 g), gestational age at birth 27 (26-40) weeks.
Interventions:
After extubation two CPAP devices (Infant Flow System vs Babylog 8000) were applied in a random order to the same infant. Fluctuations of the applied pressure during the breathing cycle and tidal breathing parameters were measured by the flow-through technique.
Main Results:
Using the Infant Flow System the mean (standard deviation) inspiratory flow [1.5 (0.1) vs 1.3 (0.1) l.min(-1).kg(-1), P<0.05] and tidal volume were significantly increased [5.3 (1.3) vs 4.7 (1.3) ml/kg(-1), P<0.05] compared to Babylog 8000. The fluctuations of the applied pressure of the Infant Flow System during the breathing cycle were significantly lower [0.1 (0.03) kPa vs 0.15 (0.08) kPa, P<0.05] compared to Babylog 8000. No differences were seen in the duration of inspiration and expiration and the time to peak tidal flow. In the Infant Flow System pressures during expiration remained stable whereas they increased during the use of Babylog 8000.
Conclusions:
Within-subject comparisons of tidal breathing parameters of the two CPAP devices Infant Flow System and Babylog 8000 show: (1) a significant influence of the system used; and (2) that the valveless Infant Flow System increases air flow and tidal volume with less fluctuations in CPAP pressures during the breathing cycle.
More Related Videos
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation I: Indication and Settings
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...