Related Experiment Video
Updated: Aug 14, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Glycemic control with different premixed insulin in Taiwanese people with type two diabetes mellitus
Ching-Chieh Su1, Harn-Shen Chen, Hong-Da Lin
1Department of Medicine, Catholic Cardinal Tien Hospital and College of Medicine, FuJen Catholic University, Taipei, Taiwan, ROC.
Background:
The aim of this study is to compare the clinical responses between Mixtard 50 HM (premixed insulin with 50% regular insulin (RI) and 50% neutral protamine Hagedom (NPH)) and Mixtard 30 HM (premixed insulin with 30% RI and 70% NPH) among type 2 diabetic patients. The acceptability of NovoPen 3 and traditional syringe was also evaluated among these patients.
Methods:
Twenty-six patients were injected with Mixtard 30 HM initially using traditional syringe, which was switched to Mixtard 50 HM eight weeks later. When the switch commenced, patients were randomly assigned to two groups. One group used traditional syringe and the other used NovoPen 3. Blood glucoses were measured before breakfast, before lunch and at bedtime for two days in a week by patients themselves. Hemoglobin A(1c)(HbA(1c)) was checked at week 8 and week 16. At the end of the trial, patients completed 1 questionnaires regarding their acceptability of NovoPen 3.
Results:
There was no statistical difference in mean blood glucose levels measured before breakfast, before lunch, or at bedtime, or in HbA(1c), between Mixtard 30 HM and Mixtard 50 HM treatment periods. However, blood glucose after breakfast declined more in Mixtard 50 HM treatment period than in Mixtard 30 HM treatment period. Up to 96.2% of the study subjects reported that NovoPen 3 was more convenient in use than traditional syringe.
Conclusions:
Blood glucose declined more from pre-breakfast level to pre-lunch level when patients used Mixtard 50 HM instead of Mixtard 30 HM. We suggest that Mixtard 50 HM is more appropriate for post-breakfast hyperglycemic diabetic patients. NovoPen 3 results in a similar clinical glycemic response but is better accepted by the patients than conventional syringe.
Related Concept Videos
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes Mellitus: Type 2 and Gestational
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into rapid-acting...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Oral Hypoglycemic Agents: Glinides
Type II Diabetes I: Introduction