Evaluation of a nontoxic rigid polymer as connecting bar in external skeletal fixators
Related Experiment Video
Updated: Sep 25, 2026

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
Christoph K Störk1, Philippe Canivet, Alexandre A Baidak
1Department of Clinical Sciences, Faculty of Veterinary Medicine and the Department of Macromolecular Chemistry and Multi-Materials, Faculty of Applied Sciences, University of Liège, Liège, Belgium. cks@vetspecialist.co.uk
Objective:
To investigate the mechanical characteristics of a nontoxic, low-cost, rigid polymer (RP) and to compare the structural and mechanical properties of a full-frame external skeletal fixator (ESF) with either RP connecting bars, polymethylmethacrylate (PMMA) connecting bars, or stainless-steel (SS) clamps and connecting bars.
Study Design:
In vitro mechanical evaluation.
Methods:
Mechanical properties were assessed using an in vitro bone fracture model with a bilateral uniplanar ESF (type II). Identical ESF were built with connecting bars using RP (n = 8), PMMA (n = 8), and SS connecting bars and clamps (System Meynard; n = 3). Nondestructive mechanical tests were performed in uniaxial compression (AC) and craniocaudal (CC) 4-point bending, as well as fatigue AC. Composite stiffness for each specimen and for each loading mode was calculated from 6 replicate measures using the slope of the load displacement curve at small displacements.
Results:
RP, PMMA, and SS ESF constructs yielded mean +/- SD composite stiffness values of 227 +/- 15, 381 +/- 30, and 394 +/- 9 N/mm in AC and of 35 +/- 2, 24 +/- 2, and 15 +/- 0 N/mm in CC, respectively.
Conclusions:
Structural and mechanical properties of RP are satisfactorily rigid and fatigue resistant for its use as a connecting bar in ESF.
Clinical Relevance:
RP connecting bars in an ESF are a reliable, versatile, nontoxic and inexpensive option for the veterinary surgeon.