A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts

Sunanda J Ram1, Jack Work, Gloria C Caldito

  • 1Interventional Nephrology Section, Division of Nephrology and Hypertension, Department of Medicine, Louisiana State University Health Sciences Center, Shreveport, Louisiana, USA.

Insights

Hemodialysis graft surveillance using flow (Qa) or stenosis measurements did not improve graft survival. While stenosis surveillance reduced thrombosis, it did not significantly enhance long-term outcomes compared to clinical monitoring alone.

Area of Science:

  • Nephrology
  • Vascular Surgery
  • Radiology

Background:

  • Graft surveillance and stenosis correction are believed to reduce thrombosis and prolong hemodialysis graft survival.
  • However, robust evidence from randomized controlled trials (RCTs) evaluating this approach is limited.

Purpose of the Study:

  • To evaluate the effectiveness of hemodialysis graft surveillance strategies, specifically flow (Qa) and stenosis monitoring, on graft survival and thrombosis rates.
  • To compare preemptive percutaneous transluminal angioplasty (PTA) rates and graft survival across different surveillance protocols.

Main Methods:

  • A randomized controlled trial involving 101 patients assigned to control, flow (Qa), or stenosis surveillance groups.
  • Monthly Qa and quarterly stenosis measurements were performed; angiography and preemptive PTA were triggered by specific criteria.
  • Follow-up extended up to 28 months to assess graft outcomes.

Main Results:

  • The preemptive PTA rate was highest in the stenosis group (0.65/patient year) compared to flow (0.34/patient year) and control (0.22/patient year) groups (P < 0.01).
  • Graft thrombosis rates were similar in control (47%) and flow (53%) groups, but reduced in the stenosis group (29%, P = 0.10).
  • Two-year graft survival rates were comparable across all groups: control (62%), flow (60%), and stenosis (64%) (P = 0.89).

Conclusions:

  • Hemodialysis graft surveillance using Qa or stenosis measurements did not demonstrate improved graft survival.
  • Although stenosis surveillance reduced thrombosis, it did not translate to superior long-term graft survival compared to aggressive clinical monitoring.
  • The study suggests that monthly Qa and quarterly stenosis measurements may not be timely or accurate indicators for preventing thrombosis or progressive stenosis.
Abstract