Evaluation of different calorimetric methods to determine the glass transition temperature and molecular mobility

I Weuts1, D Kempen, K Six

  • 1Laboratorium voor Farmacotechnologie en Biofarmacie, University of Leuven, Herestraat 49, B-3000 Leuven, Belgium.

Related Concept Videos

Phase Transitions: Melting and Freezing02:39

Phase Transitions: Melting and Freezing

Heating a crystalline solid increases the average energy of its atoms, molecules, or ions, and the solid gets hotter. At some point, the added energy becomes large enough to partially overcome the forces holding the molecules or ions of the solid in their fixed positions, and the solid begins the process of transitioning to the liquid state or melting. At this point, the temperature of the solid stops rising, despite the continual input of heat, and it remains constant until all of the solid is...
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
In Vitro Drug Dissolution: Compendial Testing Models II01:09

In Vitro Drug Dissolution: Compendial Testing Models II

Various dissolution methods are utilized to assess a drug’s dissolution rate, including the flow-through cell, paddle-over-disk, cylinder, and reciprocating disk methods.The flow-through cell apparatus (USP (United States Pharmacopeia) method 4) comprises a reservoir for the dissolution medium and a pump that propels the medium through the cell containing the test sample. This method is crucial for assessing modified-release dosage forms with minimally soluble active ingredients, maintaining...
Polymer Classification: Crystallinity01:21

Polymer Classification: Crystallinity

Unlike ionic or small covalent molecules, polymers do not form crystalline solids due to the diffusion limitations of their long-chain structures. However, polymers contain microscopic crystalline domains separated by amorphous domains.
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
In Vitro Drug Dissolution: Alternative Methods01:17

In Vitro Drug Dissolution: Alternative Methods

Alternative drug dissolution methods include the rotating bottle, intrinsic dissolution test, peristalsis, and the Franz diffusion cell method. The rotating bottle method involves meticulously rotating tightly capped controlled-release beads in a temperature-controlled bath. Periodic decanting of samples allows for residue assay, followed by refilling with fresh medium and testing at various pH levels to emulate the gastrointestinal tract conditions.In contrast, the intrinsic dissolution test...
Calorimetry01:18

Calorimetry

When objects at different temperatures are placed in contact with each other but isolated from everything else, they attain thermal equilibrium. A container that prevents heat transfer in or out is called a calorimeter, and the use of a calorimeter to make measurements is called calorimetry. Generally, these measurements involve heat or specific heat capacity. The term "calorimetry problem" is used for any problem where the specified objects are thermally isolated from their surroundings. An...