Related Experiment Video
Updated: Sep 25, 2026

Fabrication and Testing of Photonic Thermometers
Published on: October 24, 2018
Clinical thermometry: possible causes and potential solutions to electronic, digital thermometer inaccuracies
1NSL Associates, Amarillo, TX, USA. NLatman@mail.wtamu.edu
Abstract:
Previous research has indicated that the improvements in safety, speed, and ease of use of the newer electronic, digital oral and tympanic clinical thermometers have been offset by a loss in accuracy and reliability when compared with the traditional glass/mercury oral clinical thermometers. The purpose of this study was to determine possible causes of the relative lack of accuracy and reliability in these thermometers and suggest logical potential solutions. Evidence has been reviewed, which suggests that problems with the tympanic thermometers are the result of the range of normal anatomical variability. The combination of an otoscope with the tympanic thermometers is suggested and discussed as a potential solution. Evidence has been reviewed, which suggests that problems with the newer oral thermometers are the results of the size of the temperature sensors and the speed with which they respond. The small sensor size results in variability in placement relative to the primary heat source. The speed of sensor response results in too great a sensitivity to local, acute vasomotor activity (clinical temperature noise). Potential solutions, including an increase in sensor size and a reduction in response speed are discussed.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Errors occurring during blood pressure monitoring
Several factors...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...