In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Comparative study with a moving heart phantom of the impact of temporal resolution on image quality with two
Stephan Wicky1, Michael Rosol, Udo Hoffmann
1Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA. swicky@partners.org
Objective:
The objective of this study was to compare the temporal resolution-related image quality of electrocardiography-gated images acquired with two multidetector computed tomography (CT) units with a moving heart phantom, at similar fixed heart rates, using half-scan and multisector acquisition modes.
Methods:
An adjustable moving heart phantom (Limbsandthings, Horfield, Bristol, UK) was used. Specific heart rates (47, 55, 64, 66, 69, and 73 beats per minute [bpm]) were chosen. On a General Electric CT unit (LightSpeed Plus; General Electric Medical Systems, Milwaukee, WI), retrospective half-scan and multisector mode protocols were performed. On a Siemens CT unit (Somatom Volume Zoom; Siemens, Forchheim, Germany), a retrospective half-scan mode was performed at 47, 55, and 64 bpm, and a two-sector mode was performed at 66, 69, and 73 bpm. Reformatted maximum intensity projection images were qualitatively compared and related to their temporal resolution.
Results:
Half-scan mode protocols provided similar good results with both CT units up to 55 bpm. The two-sector mode improved image quality compared with the half-scan mode. High temporal resolution with the multisector mode provided the best results.
Conclusion:
For coronary artery imaging, acquisition protocols that provide the highest temporal resolution are mandatory. The multisector mode is one technique that allows high temporal resolution but may be clinically inappropriate at heart rates below 65 bpm or when heart rate variation is observed during scan time.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT