Related Experiment Video
Updated: Sep 25, 2026

The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
Published on: August 2, 2017
Relationship between umbilical and fetal cerebral blood flow velocity waveforms and umbilical venous blood gases
P Bonnin1, B Guyot, O Bailliart
1Departement d'explorations fonctionnelles, Hôpital Lariboisière, Université Paris VII, Paris, France.
Nineteen women (mean +/- SD: 28 +/- 5 years) with small fetuses relative to gestational age (mean +/- SD: 32 +/- 2.2 weeks of gestation) were referred to our unit for cordocentesis for the determination of fetal karyotyping. Four of these 19 patients had small-for-gestational-age ultrasound-derived measurements under the third centile for gestational age. Fetal blood gases were measured in the umbilical vein. Umbilical artery and fetal internal carotid artery Doppler examinations were performed 15 min before cordocentesis. The results showed a progressive and proportional increase in umbilical artery resistance index with hypoxia (p < 0.001), hypercapnia (p < 0.025) and acidosis (p < 0.005). Moreover, the results showed a progressive and proportional decrease in fetal internal carotid artery resistance index with hypoxia (p < 0.01), hypercapnia (p < 0.01) and acidosis (p < 0.025). Fetal blood gases are therefore related to umbilical circulatory function and cerebral vasodilatation, suggesting fetal vascular redistribution.
Nineteen women (mean +/- SD: 28 +/- 5 years) with small fetuses relative to gestational age (mean +/- SD: 32 +/- 2.2 weeks of gestation) were referred to our unit for cordocentesis for the determination of fetal karyotyping. Four of these 19 patients had small-for-gestational-age ultrasound-derived measurements under the third centile for gestational age. Fetal blood gases were measured in the umbilical vein. Umbilical artery and fetal internal carotid artery Doppler examinations were performed 15 min before cordocentesis. The results showed a progressive and proportional increase in umbilical artery resistance index with hypoxia (p < 0.001), hypercapnia (p < 0.025) and acidosis (p < 0.005). Moreover, the results showed a progressive and proportional decrease in fetal internal carotid artery resistance index with hypoxia (p < 0.01), hypercapnia (p < 0.01) and acidosis (p < 0.025). Fetal blood gases are therefore related to umbilical circulatory function and cerebral vasodilatation, suggesting fetal vascular redistribution.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Development of Blood Vessels
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...

