Quantitative comparison of spontaneous and paced 12-lead electrocardiogram during right ventricular outflow tract
Edward P Gerstenfeld1, Sanjay Dixit, David J Callans
1Division of Cardiology, Department of Internal Medicine, University of Pennsylvania Medical Center, 3400 Spruce Street, Philadelphia, PA 19104, USA. edward.gerstenfeld@uphs.upenn.edu
Objectives:
The purpose of this study was to objectively quantify the similarity of 12-lead electrocardiogram (ECG) waveforms using two quantitative metrics, the correlation coefficient (CORR) and the mean absolute deviation (MAD).
Background:
Comparison of the 12-lead ECG morphology between ventricular tachycardia (VT) and a pace-map is frequently performed; however, there are no objective criteria for quantifying the similarity between two waveform morphologies.
Methods:
During ablation of right ventricular outflow tract (RVOT) VT, 12-lead ECG pace-maps were acquired from three superior septal sites, three superior free wall sites, and before each ablation attempt in 15 patients. The 12-lead ECG waveforms of the clinical tachycardia and pace-maps were compared using both MAD and CORR at each site.
Results:
The MAD scores were lower (i.e., more closely matched) for septal compared with free wall sites (15.9 +/- 5.3% vs. 25.3 +/- 10.2%; p < 0.001). Successful ablation sites had a significantly lower MAD score compared with unsuccessful sites (9.5 +/- 2.8% vs. 13.3 +/- 5.6%; p = 0.01), whereas there was only a trend toward a higher CORR for successful ablation sites (98.2 +/- 1.2% vs. 96 +/- 4.7%; p = 0.07). A MAD score < or =12% was 93% sensitive and 75% specific for identifying a successful ablation site. There was an inverse correlation between MAD score and distance from the site of VT origin (r = 0.63, p < 0.001).
Conclusions:
A MAD score >12% between RVOT VT and a pace-map at any site suggests sufficient dissimilarity to dissuade ablation at that site. The MAD score can be used to standardize 12-lead ECG waveform morphology comparisons among different laboratories, and may be useful for guiding ablation of VT.
Related Concept Videos
Dysrhythmias III: Characteristics of Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias II: Classification of Tachyarrhythmias