Related Experiment Video
Updated: Sep 25, 2026

Assessment of Vascular Tone Responsiveness using Isolated Mesenteric Arteries with a Focus on Modulation by Perivascular Adipose Tissues
Published on: June 3, 2019
Examination of normalized pulse volume-blood volume relationship: toward a more valid estimation of the finger
Gohichi Tanaka1, Yukihiro Sawada
1Department of Psychology, School of Medicine, Sapporo Medical University, South 1 West 17, Chuo-ku, Sapporo 060-8556, Japan. gtanaka@sapmed.ac.jp
Abstract:
The pulsatile ac component (DeltaI) superimposed on the transmitted dc components (I: tissue plus blood) are obtained from a near-infrared finger photoplethysmogram using a wavelength of 810 nm. Only the dc component is given in an ischaemic circulatory state (I(t): tissue only). Based on Lambert-Beer's law, normalized pulse volume (NPV; =DeltaI/I) and blood volume [BV; =ln(I(t)/I)] have recently been advocated as quantitative measures. In this study, the NPV-BV relationship was examined using the finger occlusion method during rest and mental arithmetic in 16 female undergraduates. Finger vascular tone during stress was evaluated by the distance of the linear and parallel NPV-BV regression lines (D(NB)) between rest and stress conditions. A reference standard was provided by the linear regression lines of compliance index (CI=NPV/pulse pressure) and BV to the transmural pressure. The estimates at 40 mmHg of transmural pressure, as an arbitrarily chosen reference point, were calculated (CI40 and BV40). D(NB) correlated well with them (r=0.81 and 0.94, respectively). The multiple regression with mean blood pressure indicated that the combination of D(NB) and the reactivities in heart period could explain approximately 50% of valiance in pressor response. In conclusion, D(NB) is easily obtainable from the NPV-BV function and seems to be more specific and valid than NPV as an index of finger sympathetic tone, since it adjusts the mechanical effect of arterial distending pressure.
More Related Videos
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:

