Electrolyte profiles within the ileoanal pouch: measurement by an in vivo equilibrium dialysis technique
P Reissman1, E D Ehrenpreis, S Cohen
1Hadassah Hospital, Department of Surgery, Jerusalem, Israel.
Background:
Patients with an ileoanal pouch have high rates of fluid and electrolyte loss. These improve with pouch adaptation. There is limited information concerning secretion and absorption in the stable ileoanal pouch. A new method to measure and characterize electrolytes in the ileoanal pouch is described.
Methods:
Following an in vitro study, nine patients with a stable ileoanal pouch had consecutive placement of dialysis bags consisting of a semi-permeable membrane containing 5 ml of 10% dextran in normal saline into the ileoanal pouch. These were left in place for 15, 30, 60, and 120 min. After determining that 60 min was the optimal timing for measurement of electrolyte concentrations, 12 normal volunteers underwent a similar in vivo dialysis study with dialysis bags withdrawn at 60 min. Sodium, chloride, potassium, phosphorus, calcium and magnesium concentrations in the dialysis bags were compared between the two groups.
Results:
In the in vitro and in vivo studies, the measured electrolytes reached equilibrium within 60 min. Statistically significant differences between sodium concentrations (160.9 +/- 30.2 vs. 116.8 +/- 13.8 mmol/l, respectively) and phosphorus concentrations (6.8 +/- 5.2 vs. 1.8 +/- 0.7 mg/dl, respectively) at 60 min in ileoanal pouch patients and volunteers were found (p<0.001). There were no statistical differences in the other measured electrolytes between the two groups.
Conclusion:
An in vivo dialysis technique is described for measuring electrolyte concentrations within the ileoanal pouch. Differences in sodium and phosphate concentrations may reflect incomplete adaptation of the ileoanal pouch, and are a potential explanation for increased stool frequency in these patients.
More Related Videos
Related Concept Videos
Potentiometry: Membrane Electrodes
Dialysis
Ion-Exchange Chromatography
Electrochemical Systems
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Peritoneal Dialysis I: Introduction and Procedure