Related Experiment Video
Updated: Sep 25, 2026

Cavernous Nerve Stimulation and Recording of Intracavernous Pressure in a Rat
Published on: April 23, 2018
Time required to achieve a stable cuff pressure by repeated aspiration of the cuff during anaesthesia with nitrous
F Karasawa1, T Hamachi, I Takamatsu
1National Defense Medical College, Department of Anaesthesiology, Tokorozawa, Saitama, Japan. karasawa@me.ndmc.ac.jp
Background And Objective:
When the endotracheal tube cuff is repeatedly aspirated to avoid excessive cuff pressure during nitrous oxide anaesthesia, a stable cuff pressure is eventually achieved. We assessed the time required to achieve a stable cuff pressure after repeated cuff deflation.
Methods:
During 67% nitrous oxide and oxygen anaesthesia, air-filled cuffs of a standard tracheal tube (Mallinckrodt Hi-Contour) were repeatedly deflated every 30 min for the first 3 or 4 h to inhibit excessive pressure (Groups Def-3 or Def-4, respectively, n = 10 for each); the cuff pressure was monitored for an additional 3 h. In some patients, the study was terminated at 1, 2, 3 and 4 h (n = 6 for each).
Results:
Cuff pressure in Group Def-3, but not in Group Def-4, > 22 mmHg after stopping cuff aspiration. Intracuff nitrous oxide concentrations increased during repeated cuff deflation and increased further in Group Def-3 during an additional 3 h (from 39.8 +/- 4.7% to 44.3 +/- 3.8%; P < 0.05), whereas intracuff nitrous oxide concentrations at 4 h were not different from those in Group Def-4 at the end of the study (43.7 +/- 4.5% versus 42.3 +/- 4.8%; P = 0.579).
Conclusions:
When the air-filled cuff of the standard endotracheal tube is repeatedly deflated every 30 min for 4 h, but not for only 3 h, during nitrous oxide anaesthesia, a stable cuff pressure can be achieved without further deflation of the cuff. Our data also suggest that achieving an equilibrating nitrous oxide concentration in the cuff provides a subsequent stable cuff pressure.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...