Related Experiment Video
Updated: Jul 29, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Respiratory variations in the reflection mode photoplethysmographic signal. Relationships to peripheral venous
L Nilsson1, A Johansson, S Kalman
1Department of Anaesthesiology & Intensive Care, Linköping University Hospital, Linköping, Sweden. lena.nilsson@lio.se
Abstract:
Photoplethysmography (PPG) is a non-invasive optical way of measuring variations in blood volume and perfusion in the tissue, used in pulse oximetry for instance. Respiratory-induced intensity variations (RIIVs) in the PPG signal exist, but the physiological background is not fully understood. Respiration causes variations in the blood volume in the peripheral vascular bed. It was hypothesised that the filling of peripheral veins is one of the important factors involved. In 16 healthy subjects, the respiratory synchronous variations from a PPG reflection mode signal and the peripheral venous pressure (PVP) were recorded. Variations of tidal volume, respiratory rate and contribution from abdominal and thoracic muscles gave significant and similar amplitude changes in both RIIV and the respiratory variation of PVP (p<0.01). The highest amplitudes of both signals were found at the largest tidal volume, lowest respiratory rate and during mainly thoracic breathing, respectively. The coherence between PVP and RIIV signals was high, the median (quartile range) being 0.78 (0.42). Phase analysis showed that RIIV was usually leading PVP, but variations between subjects were large. Although respiratory-induced variations in PVP and PPG showed a close correlation in amplitude variation, a causal relationship between the signals could not be demonstrated.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Measurement of Blood Pressure
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...