Strain distribution within the human femur due to physiological and simplified loading: finite element analysis using the muscle standardized femur model
Related Experiment Video
Updated: Sep 25, 2026

Subject-specific Musculoskeletal Model for Studying Bone Strain During Dynamic Motion
Published on: April 11, 2018
K Polgár1, H S Gill, M Viceconti
1Oxford Orthopaedic Engineering Collaboration, Nuffield Department of Orthopaedic Surgery, University of Oxford, The Botnar Research Centre, Nuffield Orthopaedic Centre, Headington, Oxford, UK.
Abstract:
The aim of the current work was to study the effect of simplified loading on strain distribution within the intact femur using the Muscle Standardized Femur finite element model and to investigate whether the interaction between the intact human femur and the muscles which are attached to the bone surface could accurately be represented by concentrated forces, applied through the centroids of their attachment areas. An instant at 10 per cent of the gait cycle during level walking was selected as the reference physiological load case; nine load cases were analysed. Comparison of the calculated results for the physiological load case with muscle forces uniformly distributed over their attachment areas showed good agreement with in vivo measurements of strain values and femoral head displacement in humans. Simplified load cases generated unrealistic displacement results and high strain magnitudes, exceeding the physiological range. It was found that when muscles with large attachment areas are included in the model and the muscle forces are simplified, stress and strain distributions will be affected not only on the external bone surface in the vicinity of the load application node, but also on the internal surface of the cortical bone. However, applying muscle forces as concentrated loads at the centroids of the attachment areas can serve as first indicators of the physiological stress and strain levels, if results from nodes and elements in the vicinity of the load application nodes are discarded. Omitting muscle forces or fixing the femur in mid-shaft leads to large unphysiological strain values.
Related Concept Videos
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Bones of the Lower Limb: Femur and Patella
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Saint-Venant's Principle