Related Experiment Video
Updated: Sep 25, 2026

Electromyometrial Imaging of Uterine Contractions in Pregnant Women
Published on: May 26, 2023
How well do midwives estimate the date of delivery?
Elizabeth Stenhouse1, David Wright, Andrew Hattersley
1Peninsula Medical School, Universities of Exter and Plymouth, Derriford, Plymouth, UK. eistenhouse@pms.ac.uk
Objective:
to compare expected date of delivery (EDD) and gestational age (GA) obtained by midwives with those calculated using the Confidential Enquiry into Stillbirths and Death in Infancy (CESDI) recommended formula.
Design:
retrospective study of obstetric records and prospective study of clinical cases examined by multiple midwives.
Setting:
postnatal wards, Maternity Unit, Plymouth, Devon, UK.
Participants:
two studies were performed. The first was a retrospective analysis of 115 sets of obstetric records. The second, a prospective study which included five clinical cases and 19 qualified midwives whose experience ranged from six months to 25 years.
Findings:
in the retrospective study, 68 (59%) of the 115 obstetric case notes had sufficient information to apply the CESDI formula. The midwives'calculated EDD was interpreted to a GA and 35 (52.5%) agreed to within three days of the GA derived from the CESDI formula EDD. In the prospective study, the midwives' calculation of EDD was in good agreement with the CESDI formula in cases where last menstrual period (LMP) was known and menstrual cycle was 28 days with 17 (90%) of the 19 midwives providing the EDD to within three days of the CESDI formula. In the clinical case where LMP was known but menstrual cycle length was 33 days only two (10%) of the 19 calculated the EDD within three days of the CESDI formula.
Key Conclusions:
when LMP is known and the cycle length is 28 days, midwives produce results consistent with the CESDI formula. However, when the menstrual cycle differs from 28 days or LMP is unknown, inaccurate or ambiguous and obstetric ultrasound scan (USS) information is used to calculate the EDD, the midwives show varying degrees of departure from the CESDI formula. Further, we found that the midwives tended to produce underestimates when calculating GA from EDD. This bias occurs across the range of gestations covered, including early gestations when such biases may have more important medical implications.
Implications For Practice:
midwives' calculation of EDD and estimation of GA showed both random and systematic errors; in some cases, the errors were so large that they may have important medical consequences. If the CESDI-recommended formula for calculating EDD were used there would be improved accuracy and reliability of EDD and the calculation of GA.
Related Concept Videos
Midrange
Simply put, the midrange is half of the data set’s range. Similar to the mean, the midrange is sensitive to the extreme values and hence the prospective outliers. However, unlike the mean, the midrange is not sensitive to all the values of the data set that lie in the middle. Thus, it is prone to outliers and...
Midpoint Rule
Uncertainty in Measurement: Reading Instruments
In Vitro Fertilization
The IVF process begins with ovarian stimulation, during which reproductive endocrinologists prescribe hormonal medications to stimulate the ovaries to produce multiple eggs instead of the single...
