Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites
1Regional Medical Physics Department, Freeman Hospital, Newcastle upon Tyne NE7 7DN, UK. john.allen@nuth.northy.nhs.uk
Abstract:
It is accepted that older subjects have increasing arterial stiffness resulting in changes in the propagation of the pulse to the periphery, and thereby influencing the peripheral pulse timing and shape characteristics. However, this age association with pulse shape is less clear in younger subjects and for different peripheral measurement sites. The aim of this study was to determine the association between age and changes in pulse shape characteristics at the ears, fingers and toes. Photoplethysmography pulse waveforms were recorded non-invasively from the right and left sides at the ears, index fingers and great toes of 116 normal healthy human subjects. Their median age was 41 years (range 13-72) allowing four distinct age groups to be considered (subjects younger than 30 years, 30-39 years, 40-49 years and 50 years of age or older). Normalized ear, finger and toe pulse shapes were calculated, for the whole subject group, and for the subjects within each age group. The differences in shape, relative to the oldest group, were also calculated for two distinct regions of interest: the systolic rising edge and the dicrotic notch of the pulse. Subtle, gradual and significant changes in the pulse shape were found at all sites with overall elongation of the systolic rising edge (p < 0.05) and damping of the dicrotic notch (p < 0.05) with age. The overall age-related changes in multi-site PPG pulse shape characteristics at the ear, finger and toe sites have been demonstrated and quantified. Age-matched normal ranges must be considered when evaluating pulses from patients with possible vascular disease.
Related Concept Videos
Special considerations while measuring pulse
Pulse Assessment Sites
Pulse
The pulse serves as a clinical indicator...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...