Related Experiment Video
Updated: Aug 9, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures
1Department of Cardiology, Klinik Fraenkische Schweiz, Feuersteinstr. 2, D-91320 Ebermannstadt, Germany.
Abstract:
The goal of this study was to improve radiation dose reduction techniques in invasive cardiology and after patients' radiation data had approached minimal levels, to evaluate predictors of their radiation exposure resulting from invasive cardiac procedures. Over the course of 1 year (and 1996 procedures) we minimized cinegraphic frames and runs, as well as fluoroscopy time, and trained ourselves to achieve effective fluoroscopy-saving positioning of blinds and filters toward the regions of interest. We were consequently able to reduce the mean dose-area products (DAP) for coronary angiography and angioplasty, combined interventions, high-frequency rotational atherectomy, and excimer laser angioplasty: from levels of 53.9 Gy cm(2), 79.6 Gy cm(2), 112.3 Gy cm(2), 119.4 Gy cm(2), and 168.0 Gy cm(2) as currently reported in the literature, to 12.9 Gy cm(2), 13.3 Gy cm(2), 25.9 Gy cm(2), 33.0 Gy cm(2), and 27.1 Gy cm(2), respectively. The mean DAP due to interventions in acute myocardial infarction was 38.3 Gy cm(2). DAP was influenced by body mass index, complexity of coronary artery disease, tube angulation, documented structure, coronary recanalization, emergency circumstances, and the percutaneous transluminal coronary angioplasty (PTCA) target vessel involved, but not by stent implantation. By favouring radiation-reducing cranial posteroanterior views over standard left anterior oblique views for visualization of the left anterior descending and the diagonal artery, we consequently achieved mean PTCA-DAPs of 10.4 Gy cm(2) and 8.6 Gy cm(2), respectively: levels significantly lower than those for PTCA of the right coronary artery (13.3 Gy cm(2)), left circumflex artery (13.7 Gy cm(2)), and obtuse marginal branch (16.9 Gy cm(2)). In conclusion, enhanced knowledge of radiation dose-reduction techniques significantly reduces patient radiation hazards in invasive cardiology.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management