Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Parallel spectroscopic imaging with spin-echo trains.

Ulrike Dydak1, Klaas P Pruessmann, Markus Weiger

  • 1Institute for Biomedical Engineering, University of Zurich and Swiss Federal Institute of Technology Zurich, Zurich, Switzerland.

Magnetic Resonance in Medicine
|June 20, 2003
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Prospective Head Motion Correction in T1- and T2-Weighted Long Echo Train Sequences Using Servo Navigation.

Magnetic resonance in medicine·2026
Same author

Direct MRI of collagen.

eLife·2026
Same author

The sinking dynamics of a solid intruder in concentrated cornstarch suspensions studied using ultra-fast magnetic resonance imaging.

Soft matter·2026
Same author

Core-shell particles with tailored magnetic susceptibility for signal-efficient magnetic resonance imaging of granular systems.

Journal of magnetic resonance (San Diego, Calif. : 1997)·2026
Same author

Autonomy for MRI Field Cameras: Synchronization, Self-Calibration, and Sequence Detection.

Magnetic resonance in medicine·2026
Same author

Motion- and Field-Robust Mesoscopic Whole-Brain <math><semantics><mrow><msubsup><mi>T</mi> <mn>2</mn> <mo>*</mo></msubsup></mrow> <annotation>$$ {T}_2^{\ast } $$</annotation></semantics></math> -Weighted Imaging at 7 and 11.7 T Using Servo Navigation.

Magnetic resonance in medicine·2026
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
Same journal

Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.

Magnetic resonance in medicine·2026
Same journal

Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.

Magnetic resonance in medicine·2026
Same journal

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID-Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI).

Magnetic resonance in medicine·2026
See all related articles

This study introduces an ultrafast spectroscopic imaging (SI) technique combining multiple spin-echo (MSE) acquisition and sensitivity encoding (SENSE). This novel method significantly reduces scan times for high-resolution SI, demonstrating clinical feasibility.

Area of Science:

  • Medical Imaging
  • Spectroscopic Imaging
  • Magnetic Resonance Imaging

Background:

  • Reducing scan time in spectroscopic imaging (SI) is crucial for clinical applications.
  • Traditional SI methods often require lengthy acquisition times, limiting patient throughput and comfort.
  • Fast sampling and reduced k-space coverage are common strategies to accelerate SI.

Purpose of the Study:

  • To present and evaluate an ultrafast SI technique combining multiple spin-echo (MSE) acquisition and sensitivity encoding (SENSE).
  • To assess the trade-off between scan time, signal-to-noise ratio (SNR), and spatial response for the proposed MSE-SENSE-SI method.
  • To demonstrate the clinical feasibility of the ultrafast SI technique in a patient study.

Main Methods:

  • Developed an ultrafast SI technique integrating MSE acquisition with SENSE.

Related Experiment Videos

  • Evaluated MSE-SENSE-SI with varying echo train lengths (1-4 echoes) using in vitro experiments.
  • Assessed SNR and spatial response function characteristics.
  • Demonstrated clinical feasibility in a patient with an astrocytoma.
  • Main Results:

    • Acquiring two spin-echoes (SEs) per acquisition provided an optimal balance between scan time, SNR, and spatial response.
    • The MSE-SENSE-SI technique enabled high-resolution SI acquisition within a clinically acceptable timeframe.
    • Successful SI data acquisition was achieved in a patient with an astrocytoma in just over 2 minutes with a 24x24 matrix.

    Conclusions:

    • The combined MSE and SENSE approach offers a significant reduction in spectroscopic imaging scan time.
    • MSE-SENSE-SI presents a practical and effective solution for accelerating high-resolution SI.
    • The technique shows promise for routine clinical use in neuro-oncology and other applications requiring rapid SI.