Otoacoustic emissions in patients with hypotension
Dimitrios G Balatsouras1, Stavros Korres, Nikola Simaskos
1Department of Otolaryngology, Tzanion General Hospital, Piraeus, Greece. dbalats@hotmail.com
Abstract:
The aim of this study was to investigate the relation between hypotension and slowly developing hearing impairment, using otoacoustic emissions. A group of 42 patients was examined, with diastolic blood pressure < or = 60 mmHg and systolic blood pressure < or = 105 mmHg. The subjects underwent biochemical, cardiological, ENT and audiological examinations. Distortion product otoacoustic emissions (DPOAE) were recorded in the format of DP-gram. The results were compared to the data of 30 normal persons of similar age and sex, examined at the same laboratory. Audiometric results showed that 18 patients had mild or moderate symmetrical hearing loss in one or more frequencies, mainly in the lower frequency range. DPOAE of the patients had reduced amplitude as compared to controls or were even absent, in one or more frequencies. It may be concluded that a hypotensive condition could be a possible factor in the origin of cochlear damage and DPOAE may be useful in monitoring hypotensive patients.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Korotkoff Sounds
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)