Related Experiment Video
Updated: Sep 23, 2026

Assessing Respiratory Immune Responses to Haemophilus Influenzae
Published on: June 29, 2021
Association between inflammatory mediators and the fibrinolysis system in infectious pleural effusions
Carmen Alemán1, José Alegre, Jasone Monasterio
1Department of Internal Medicine, Vall d'Hebron University Hospital, Barcelona, Spain. 29261cal@comb.es
Abstract:
The response of the fibrinolytic system to inflammatory mediators in empyema and complicated parapneumonic pleural effusions is still uncertain. We prospectively analysed 100 patients with pleural effusion: 25 with empyema or complicated parapneumonic effusion, 22 with tuberculous effusion, 28 with malignant effusion and 25 with transudate effusion. Inflammatory mediators, tumour necrosis factor-alpha (TNF-alpha), interleukin-8 (IL-8) and polymorphonuclear elastase, were measured in serum and pleural fluid. Fibrinolytic system parameters, plasminogen, tissue-type plasminogen activator (t-PA) and urokinase PA, PA inhibitor type 1 (PAI 1) and PAI type 2 concentrations and PAI 1 activity, were quantified in plasma and pleural fluid. The Wilcoxon signed-rank test was used to compare plasma and pleural values and to compare pleural values according to the aetiology of the effusion. The Pearson correlation coefficient was used to assess the relationship between fibrinolytic and inflammatory markers in pleural fluid. Significant differences were found between pleural and plasma fibrinolytic system levels. Pleural fluid exudates had higher fibrinolytic levels than transudates. Among exudates, tuberculous, empyema and complicated parapneumonic effusions demonstrated higher pleural PAI levels than malignant effusions, whereas t-PA was lowest in empyema and complicated parapneumonic pleural effusions. PAI concentrations correlated with TNF-alpha, IL-8 and polymorphonuclear elastase when all exudative effusions were analysed, but the association was not maintained in empyema and complicated parapneumonic effusions. A negative association found between t-PA and both IL-8 and polymorphonuclear elastase in exudative effusions was strongest in empyema and complicated parapneumonic effusions. Blockage of fibrin clearance in empyema and complicated parapneumonic effusions was associated with both enhanced levels of PAIs and decreased levels of t-PA.
Related Concept Videos
Acute Inflammation III: Local and Systemic Effects
Pleural Effusion I: Introduction
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's criteria,...
Inflammatory Response II: Inflammatory Exudate and Tissue Repair
The typical wound exudate is odorless, transparent, straw-colored, thin, and watery. Exudate, however, can differ depending on the state of wound healing. Likewise, the exudate's...
Acute Inflammation I: Inflammatory Response
Chronic Inflammation: Introduction
Inflammation