The effect of axial length on ocular blood flow assessment in anisometropes
Andrew K C Lam1, Suk-Tak Chan, Ben Chan
1Department of Optometry and Radiography, The Hong Kong Polytechnic University, Hong Kong SAR, China. orkclam@polyu.edu.hk
Background:
Pulsatile ocular blood flow (POBF) assessment measures the choroidal circulation and therefore provides data with diagnostic value in certain ocular diseases, such as glaucoma. The technique assumes a constant pressure-volume relationship. The current study investigated the effect of axial length on POBF from subjects with axial anisometropia. Ocular blood supply in the ophthalmic artery was also determined using colour Doppler ultrasonography.
Methods:
Thirty-one normal, anisometropic subjects were recruited, whose ages ranged from 20 to 34 years. They had axial anisometropia (expressed by spherical equivalent) of at least 2 D. After Goldmann tonometry, the POBF of each eye was measured in a supine posture by one examiner, followed by a measurement of the blood flow velocity in the ophthalmic artery using colour Doppler ultrasonography in the same posture by another examiner. There was a 10 min rest between the two techniques. All the measurements were made at around the same time to eliminate any effect from diurnal variation.
Results:
The mean anisometropia (expressed by spherical equivalent) was 3.89 +/- 1.96 D and the mean inter-ocular axial length difference was 1.49 +/- 1.00 mm. The anisometropia and axial length were significantly different between the two eyes (paired t-tests: p < 0.001). However, the intra-ocular pressure was similar between the two eyes (paired t-test: p = 0.41). The POBF was significantly lower in the eye with the longer axial length (459.3 microL min-1) than the fellow eye (590.8 microL min-1), paired t-test: p < 0.001. The pulse amplitude was also significantly lower in the eye with the longer axial length (1.61 mmHg) than the fellow eye (1.89 mmHg), paired t-test: p < 0.001. However, the blood flow velocity from colour Doppler ultrasonography did not demonstrate any significant difference between the two eyes (paired t-test: p > 0.05).
Conclusions:
The POBF and pulse amplitude were found to be reduced in the eye with the longer axial length but colour Doppler ultrasonography did not show any significant difference. This suggests that a new pressure-volume relation should be considered in deriving POBF. Practitioners should measure the axial length in POBF assessment.
More Related Videos
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Focusing of Light in the Eye