Related Experiment Video
Updated: Jul 11, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Elasticity of alveolar bone near dental implant-bone interfaces after one month's healing
1Department of Oral Sciences, Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, 16-212 Moos Tower, 515 Delaware Street SE, Minneapolis, MN 55455, USA.
Abstract:
Information is scarce about Young's modulus of healing bone surrounding an implant. The purpose of this preliminary study is to quantify elastic properties of pig alveolar bone that has healed for 1 month around titanium threaded dental implants, using the nanoindentation method. Two 2-year-old Sinclair miniswine were used for the study. Nanoindentation tests perpendicular to the bucco-lingual cross section were performed on harvested implant-bone blocks using the Hysitron TriboScope III. Nomarski differential interference contrast microscopy was used to identify pyramidal indentation measurements that were from bone. Reduced moduli, averaged for all anatomical regions, were found to start low (6.17 GPa) at the interface and gradually increase (slope=0.014) to a distance of 150 microm (7.89 GPa) from the implant surface, and then flatten to a slope of 0.001 from 150 to 1500 microm (10.13 GPa). Mean reduced modulus and its relationship to distance did not differ significantly by anatomic location (e.g., coronal, middle, and apical third; P>/=0.28 for all relevant tests) at 1 month after implantation.