Related Experiment Video
Updated: Sep 23, 2026

Establishment of a Novel Ex Vivo Lung Perfusion System for Rat Lungs After Circulatory Death
Published on: October 18, 2024
Transplantation of lungs from non-heart-beating donors after functional assessment ex vivo
Stig Steen1, Qiuming Liao, Per N Wierup
1Department of Cardiothoracic Surgery, Heart-Lung Division, University Hospital of Lund, Lund, Sweden. stig-steen@thorax.lu.se
Background:
If lungs from patients dying of heart attacks are to serve as donor organs in a safe way, their function should be properly assessed before transplantation. The aim of this study was to investigate donor lung function evaluation in a realistic large animal model.
Methods:
Twelve 60-kg pigs were used. Five minutes after ventricular fibrillation was induced, cardiopulmonary resuscitation was initiated and maintained for 20 minutes. After a 10-min hands-off period, heparin was administered through a central venous catheter followed by 20 chest compressions. Intrapleural cooling was initiated after 65 minutes of warm ischemia. Cooling proceeded for 6 hours within the cadaver, after which lung function was assessed ex vivo. Recipient pigs underwent left lung transplantation followed by right pneumonectomy, thus making these animals 100% dependent for their survival on the function of the donor lungs.
Results:
The assessment showed that all lungs had adequate function to serve as donor lungs. All recipient animals were in good condition during the 24-hour observation period after the operation. The blood gas function did not differ significantly from that in the healthy donor animals before induction of ventricular fibrillation; pulmonary vascular resistance was within normal range.
Conclusions:
Lungs from non-heart-beating donors topically cooled in situ for 6 hours after 65 minutes of warm ischemia were assessed ex vivo and found to have normal function. They were then transplanted and retained normal function during a 24-hour observation period.