Navin C Nanda1, Dalane W Kitzman, Howard C Dittrich
1University of Alabama at Birmingham, Heart Station SW/S102, 619 19th Street, Birmingham, AL 35249, USA. nanda@uab.edu
Background:
This study was conducted to assess the ability of a new echocardiographic contrast agent, Imagent (perflexane lipid microspheres; Alliance Pharmaceutical Corp., San Diego, CA), to improve endocardial border delineation (EBD) and assessment of segmental wall motion (SWM). This was achieved by analysis of inter-reader agreement by echocardiography and comparison with an independent imaging technique, magnetic resonance imaging (MRI).
Methods:
Two separate, independent, prospective, randomized, controlled, multicenter trials were conducted at 26 centers and included a total of 409 efficacy-evaluable patients. In Study A 206 patients were randomized to receive either Imagent or saline and in Study B, 203 patients received Imagent with a subset imaged by both echocardiography and MRI. All patients were required to have suboptimal baseline images using fundamental imaging. Images were optimized at baseline prior to contrast and the settings maintained post-contrast. Imagent, a suspension of perfluorohexane-filled spheres with flexible lipid shells, was administered as an IV bolus at 0.125 mg/kg body weight. Gated MRI studies were performed within 48 hours of dosing in a subset of 26 subjects. Six expert independent blinded readers reviewed unpaired noncontrast and contrast exams and scored EBD and SWM. Analysis of inter-reader agreement was performed by comparing the SWM score (1 to 5) recorded by each reader pair. In addition, unanimity between readers for SWM was evaluated. For comparison to MRI, the results from echo readers 4, 5, and 6 were each compared with a single independent MRI reader.
Results:
The patients enrolled in these clinical trials displayed markedly suboptimal images with 49% and 71% (Study A and Study B) of the segments determined by the readers to be suboptimal prior to contrast administration. All readers recorded statistically significant (P < 0.0001) improvement in total EBD scores following the administration of Imagent. Comparison of noncontrast SWM scores for each pair of echo readers resulted in agreement in an average of 39%, of segments in Study A, and 31% of the segments in Study B. Use of Imagent improved agreement in SWM scores to 65% in Study A, and 48% of segments in Study B (P < 0.0001) for all reader pairs in both studies. Reader unanimity in SWM scores increased from 13% to 41% of the segments with the administration of Imagent. Blinded review of the noncontrast echo examinations resulted in agreement with MRI derived SWM scores in 15% of the segments. The administration of Imagent improved this agreement to 47%, of the segments (P < pr = 0.0005 for each blinded reader).
Conclusions:
Use of Imagent during echocardiographic imaging improves EBD, providing a significant improvement in inter-reader agreement in SWM evaluation with echo and greater than a threefold improvement in SWM scoring accuracy with MRI.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System IV: CMRI