Related Experiment Video
Updated: Aug 7, 2026

Assessing Endothelial Vasodilator Function with the Endo-PAT 2000
Published on: October 15, 2010
Assessment of peripheral vascular endothelial function with finger arterial pulse wave amplitude
Jeffrey T Kuvin1, Ayan R Patel, Kathleen A Sliney
1Department of Medicine, Division of Cardiology, Tufts-New England Medical Center Hospitals, Tufts University School of Medicine, Boston, MA 02111, USA. jkuvin@tufts-nemc.org
Background:
Abnormalities in pulse wave amplitude (PWA) have been described in subjects with atherosclerosis and may be a marker of future cardiac events. We evaluated the relationship between changes in PWA of the finger and peripheral endothelial function.
Methods:
We performed measurements of PWA with a novel finger plethysmograph (peripheral arterial tonometry [PAT]) and compared the findings with a simultaneous noninvasive measurement of peripheral endothelial function with brachial artery ultrasound scanning (BAUS) in 89 subjects. The PAT hyperemia ratio was defined as the ratio of PWA during reactive hyperemia relative to the baseline. Flow-mediated dilation (FMD) was defined by BAUS as the ratio of the brachial artery diameter during reactive hyperemia relative to the baseline. Sixty-eight subjects underwent exercise myocardial perfusion imaging (ExMPI).
Results:
Fifty-four men and 35 women were examined. There was a linear relationship between the PAT hyperemia ratio and FMD during the same episode of reactive hyperemia (r = 0.55, P <.0001). Subjects in the lowest FMD quartile had the lowest PAT hyperemia ratio, whereas subjects in the highest FMD quartile had the highest PAT hyperemia ratio (P <.001 for trend). Similar to BAUS, the PAT hyperemia ratio was more impaired in subjects with cardiovascular risk factors and in subjects with ExMPI studies that were indicative of coronary artery disease.
Conclusions:
Assessment of PWA with PAT demonstrates patterns of abnormality similar to that of BAUS assessment of FMD. PWA during reactive hyperemia is influenced by factors known to affect endothelial function, including cardiovascular risk factors and coronary artery disease. These findings support the concept that analysis of PWA with PAT during reactive hyperemia may be used to study peripheral vascular endothelial function.
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation