Related Experiment Video
Updated: Sep 23, 2026

CT-guided Preoperative Localization of Pulmonary Nodules Using a Glucose Test and Tissue Adhesive
Published on: January 30, 2026
Radioisotope marking under CT guidance and localization using a handheld gamma probe for small or indistinct
Kazuro Sugi1, Yoshikazu Kaneda, Katutoshi Hirasawa
1Department of Clinical Research, Sanyo National Hospital, Ube, Japan. ksugi@sanyou.hosp.go.jp
Study Objectives:
A new marking technique was developed to localize small or indistinct pulmonary lesions, involving preoperative radioisotope injection and intraoperative detection with a handheld gamma probe.
Setting:
National hospital for respiratory disease.
Methods:
and patients: A technetium suspension (either (99m)Tc tin colloid [2 to 4 mCi, 0.5 to 2.5 mL] or (99m)Tc phytate [2 mCi, 2.0 mL]) was injected preoperatively in the vicinity of the lesion under CT guidance in 25 patients with small or indistinct pulmonary lesions. A handheld gamma probe (Navigator GPS; Tyco Healthcare Japan; Tokyo, Japan) was used to detect the hot spot where radioactivity was localized during surgery. The lesion marked by the radioisotope then was thoracoscopically resected using endostaplers.
Results:
The preoperative marking procedure took approximately 30 min. A small pneumothorax and mild intrapulmonary bleeding were observed in two patients and one patient, respectively, but no additional treatment was needed for these complications. The lesion was resected soon after the marking procedure in 21 patients, and on the next day in 4 patients. All lesions were easily identified during surgery as radioactive hot spots detected by the handheld gamma probe. Thoracoscopic wedge resection was successfully performed in all patients without complications.
Conclusion:
This new marking technique for small or indistinct pulmonary lesions (radioisotope injection under CT guidance and intraoperative detection with a handheld gamma probe) seems to be safe, reliable, and convenient.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...