Cyclic changes in arterial pulse during respiratory support revisited by Doppler echocardiography
Antoine Vieillard-Baron1, Karim Chergui, Roch Augarde
1University Hospital Ambroise Paré, Assistance Publique Hôpitaux de Paris, France.
Abstract:
It has long been known that there are cyclic changes in arterial pressure during mechanical ventilation. They are caused by cyclic changes in both the right and left ventricular stroke output, occurring in opposite phases. As a result, arterial pulse pressure is increased during inspiration and decreased during expiration. A cyclic improvement in left ventricular systolic function could thus be expected during mechanical lung inflation. We tested this hypothesis in 31 septic patients who were mechanically ventilated in controlled mode by combining left ventricular measurements by transesophageal echocardiography with invasive arterial pressure recordings and Doppler analysis of pulmonary venous flow and right and left ventricular stroke volume. Lung inflation by tidal ventilation significantly improved left ventricular stroke volume (26 +/- 0.4 cm3/m2 [mean +/- SEM] vs. 22.3 +/- 0.4 cm3/m2 at end deflation). Beat-to-beat analysis of pulmonary venous flow velocity illustrated the boosting effect of lung inflation on pulmonary venous return. The beneficial effect of inspiration thus appeared directly related to a significant increase in left ventricular diastolic volume (60.3 +/- 1.5 cm3/m2 vs. 53.3 +/- 1.4 cm3/m2 at end-expiration) and to a lesser extent to an improved left ventricular ejection fraction. We concluded that the transient beneficial hemodynamic effect of tidal ventilation on the left ventricular pump is essentially mediated by an improved left ventricular filling.
Related Concept Videos
Special considerations while measuring pulse
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Pulse
The pulse serves as a clinical indicator...