Related Experiment Videos
Linear attenuation coefficients of tissue-equivalent materials of differing compositions for low energy photons
1Environmental Assessment Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.
Abstract:
Total linear attenuation coefficients of three tissue equivalent materials differing in their fat contents were experimentally determined for low energy photons in the range 13-51 keV. It is found that their variations with photon energy for each of these materials are describable by two distinct power functions with the validity ranges being (13-23 keV) and (32-51 keV), respectively. Therefore, to adequately represent the variation of total linear attenuation coefficients over the full photon energy range i.e., 13-51 keV, a sum of two power functions is needed. Least squares fitted equations to the entire experimental data are thus included. For muscle, the experimental data show a reasonably good agreement with the theoretically computed values that are available in literature.