[Examination of SUV of regional activity concentration for simultaneous emission/transmission acquisition using the
Shinji Abe1, Masanari Nishino, Masato Yamashita
1Department of Radiology, Nagoya University Hospital.
Abstract:
To achieve quantitative accuracy of simultaneous emission/transmission (SET) acquisition using the mask technique, we determined the factor of expression that derives the true transmission data from the measured transmission and emission data. We then evaluated the standardized uptake value (SUV) of the regional activity concentration derived respectively from the SET scans and conventional scans. First, to determine the attenuation factor for the transmission source when the photons of the cylindrical phantom filled with (18)F solution reached emission memory, SET scans were performed with a dummy transmission source and under the blank status of the transmission source. Second, to evaluate the SUV, we used a hollow-sphere phantom filled with (18)F solution whose activity concentrations were approximately 3 and 5 times that of the background. Then we performed conventional and SET scans of the phantom for solutions ranging from the higher concentration to the lower concentration. All of the data were reconstructed with the decay correction, and the SUV of each sphere was derived. The results demonstrated that, when the conventional factor was used, SUV was underestimated according to the increasing activity concentration of the solution. However, when a new factor that took into account the attenuation of the transmission source was used, there was no significant difference in the SUV. We estimated the SUV derived from the SET scans was within 3% for the large spheres and within 16% for the small spheres.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Interference
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab