Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
Published on: August 18, 2017
Chiroptical detection during liquid chromatography: Deconvolution of overlapping peaks of enantiomers and its
Roland Kiesswetter1, Friedrich Brandl, Nikola Kastner-Pustet
1Institut für Organische Chemie, Universität Regensburg, Regensburg, Germany.
Abstract:
The peaks of enantiomers in liquid chromatography (LC) frequently overlap for different reasons. The experimental curve can be deconvolved, i.e., transformed into the two curves of the enantiomers, without any assumption concerning their peak shapes. Besides the usual photometric UV detection, resulting in absorbance A, polarimetric or circular dichroic detection is required, providing the rotation 90 degree angle alpha or the differential absorbance DeltaA, respectively. The accuracy of the ratio alpha/A or DeltaA/A for the pure enantiomers is essential for the quality of the deconvolution. The determination of these ratios, using the overlapping peaks, and the subsequent computer deconvolution of the latter are discussed in more detail than in the earlier publications, e.g. Ref. 1 concerning this particular method. The computer program developed for this purpose is characterized. A condition is given which limits the availability of ratios and, therefore, the possibility of deconvolution. Several novel examples are described which stem from the following fields of application of deconvolved peaks: actual optical purities during LC (on-line analysis), overall optical purity of a sample, purities of chromatographic peaks, and, finally, enantiomerization during LC.
More Related Videos
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Properties of Enantiomers and Optical Activity
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...