Use of solid-phase microextraction coupled with gas chromatography for the determination of residual solvents in
Stéphanie Legrand1, José Dugay, Jérôme Vial
1Laboratoire Environnement et Chimrie Analytique, UMR 7121, Ecole Supérieure de Physique et Chimie Industrielles de la Ville de Paris, 10 Rue Vauquelin, 75005 Paris, France.
Abstract:
The aim of this work was to prove that solid-phase microextraction coupled with gas chromatography could be used for the determination and quantification of residual solvents in drugs. Four solvents were selected for the experiments: ethanol, cyclohexane, triethylamine and pyridine, together with a model powdered drug substance. Several kinds of fibers, together with the extraction mode, were evaluated to determine the most appropriate one for the simultaneous extraction of the four solvents. The most promising conditions were obtained with the Carboxen-polydimethylsiloxane fiber in the headspace of the aqueous solution that contained the dissolved powder. A concentrated phosphate buffer was added to the aqueous solution to set the pH at 9.6 in order to enable good extraction of triethylamine, and the optimum extraction time was experimentally determined. A multi-criteria optimization was also carried out by means of design of experiments to optimize remaining parameters: the extraction temperature was set at 40 degrees C, the ionic strength at 1.77 mol (l-1) and the volume of the aqueous solution at 7.2 ml. The method of standard additions was used for quantitative analysis. Its performance was evaluated and validated: the pooled RSD was around 15%, the limits of detection were all of the ppb level and the method was both accurate and linear.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...