Low-dose low-osmolar urography with iohexol.

Rakhee Gupta1, Raj Kumar Airon

  • 1Department of Radiodiagnosis, Pt. BD Sharma Postgraduate Institute of Medical Sciences, Rohtak, India. tinysam@glide.net.in

Urologia Internationalis
|August 2, 2003
PubMed
Summary

Low-dose iohexol (90 mg iodine/kg) is safe and effective for intravenous urography. This study found it provided satisfactory diagnostic information in 94% of patients with minimal adverse reactions.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Clinical and Immunological Profiles With Treatment Patterns in Systemic Lupus Erythematosus Patients in the Eastern Part of India: A Retrospective, Hospital-Based, Cross-Sectional Study.

Cureus·2026
Same author

Cutaneous Entomophthoromycosis from Bihar: A Report of Three Cases and Review of Literature.

Indian journal of dermatology·2023
Same author

Evaluation of Multidetector Computed Tomography in Haematuria.

Maedica·2017
Same author

Colour Doppler sonography of flaccid penis in evaluation of erectile dysfunction.

Asian journal of surgery·2007
Same author

Associated anomalies with anorectal malformation (ARM).

Indian journal of pediatrics·2004
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Area of Science:

  • Radiology
  • Diagnostic Imaging
  • Urology

Background:

  • Intravenous urography (IVU) is a key diagnostic tool for urinary system evaluation.
  • Optimizing contrast agent dosage is crucial for balancing diagnostic efficacy and patient safety.

Purpose of the Study:

  • To evaluate the diagnostic performance of a low dose of iohexol for IVU.
  • To assess the safety profile of low-dose iohexol in patients undergoing IVU.

Main Methods:

  • Fifty patients with urinary complaints underwent IVU using low-dose iohexol (90 mg iodine/kg).
  • Patients with renal insufficiency (elevated blood urea and serum creatinine) were excluded.
  • Image quality and diagnostic information were assessed, and adverse reactions were monitored.

Main Results:

  • A satisfactory diagnosis was achieved in 94% of the patients.
  • Only one patient experienced a minor adverse reaction (heat sensation), which required no treatment.
  • The low dose of iohexol demonstrated good diagnostic yield for renal parenchyma, calyces, and the collecting system.

Conclusions:

  • Low-dose iohexol (90 mg iodine/kg) is a safe and diagnostically effective agent for routine IVU.
  • This dosage offers a favorable risk-benefit profile for evaluating various urinary complaints.