Prospective blinded evaluation of computed tomographic colonography for screen detection of colorectal polyps
C Daniel Johnson1, William S Harmsen, Lynn A Wilson
1Department of Radiology, Mayo Clinic Rochester, 200 First Street S.W., Rochester, Minnesota 55905, USA.
Background & Aims:
This study used a low lesion prevalence population reflective of the screening setting to estimate the sensitivity and specificity of computerized tomographic (CT) colonography for detection of colorectal polyps.
Methods:
This prospective, blinded study comprised 703 asymptomatic persons at higher-than-average risk for colorectal cancer who underwent CT colonography followed by same-day colonoscopy. Two of 3 experienced readers interpreted each CT colonography examination.
Results:
Overall lesion prevalence for adenomas >/=1 cm in diameter was 5%. Seventy percent of all lesions were proximal to the descending colon. With colonoscopy serving as the gold standard, CT colonography detected 34%, 32%, 73%, and 63% of the 59 polyps >/=1 cm for readers 1, 2, 3, and double-reading, respectively; and 35%, 29%, 57%, and 54% of the 94 polyps 5-9 mm for readers 1, 2, 3, and double-reading, respectively. Specificity for CT colonography ranged from 95% to 98% and 86% to 95% for >1 cm and 5-9-mm polyps, respectively. Interobserver variability was high for CT colonography with kappa statistic values ranging from -0.67 to 0.89.
Conclusions:
In a low prevalence setting, polyp detection rates at CT colonography are well below those at colonoscopy. These rates are less than previous reports based largely on high lesion prevalence cohorts. High interobserver variability warrants further investigation but may be due to the low prevalence of polyps in this cohort and the high impact on total sensitivity of each missed polyp. Specificity, based on large numbers, is high and exhibits excellent agreement among observers.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography