Abstract:
During the last 30 years, there has been an unexplained trend toward declining values for plethysmographic assessments of lung volume at functional residual capacity (FRC) in infants. The aim of this study was to compare data collected from healthy infants using contemporary equipment with published reference data and to explore reasons for discrepancies. Lung volumes were measured in 32 healthy infants (age, 4-93 weeks; weight, 3.9-12.4 kg) using a new, commercially available infant plethysmograph. Mean (SD) FRC was 19.6 (3.4) ml/kg (within subject coefficient of variation 3.4 [2.3%]), which was on average 7.0 [3.5] ml/kg and 2.3 [1.2] SD (Z) scores lower than the recently collated reference data from an American Thoracic Society task force. A total of 66% of these healthy infants had a FRC that was below the predicted normal range. Comparison of equipment, software, and protocols with those from previous reports revealed the importance of minimization of dead space and of adequate subtraction of all compressible occluded volume when calculating FRC in infants. These findings emphasize the need to establish reference data for lung function tests in infants that are appropriate for the equipment and protocols in current use.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Related Concept Videos
Breathing
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Pulmonary Cycle: Exhalation
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Atelectasis II: Pathophysiology